Running a business in Ontario comes with plenty of expenses, and electricity can be one of the hardest to predict.
For warehouses, manufacturing facilities, and commercial buildings across Toronto and the Greater Toronto Area, electricity costs aren't always determined by how much energy is consumed. Depending on the business's electricity rate, the amount of power needed at a particular time can also affect the bill.
Think about a manufacturing facility where several machines start running at once, or a warehouse where cooling systems and other equipment are operating simultaneously.
These periods of high electricity demand can make a difference in what some businesses pay.
That's why peak shaving is worth understanding. It's an energy management strategy that can help certain Ontario businesses reduce how much electricity they draw from the grid during high-demand periods.
And battery storage is one way to do it.
Peak shaving means reducing the amount of power your building draws from the electricity grid when demand is at its highest.
Here's a simple example.
A manufacturing facility normally draws 150 kilowatts (kW) of power. During its busiest operating hours, several machines run simultaneously, increasing demand to 250 kW.
If the facility has a properly sized battery system, it could use stored electricity to supply part of that extra power.
Instead of drawing 250 kW entirely from the grid, the facility might draw 150 kW from the grid and supply the remaining 100 kW from its battery.
For businesses with demand-based electricity charges, reducing these spikes may help lower certain billing costs.
The actual savings depend on the electricity rate structure, battery capacity, and how long the periods of high demand last.
Not every business in Ontario pays for electricity in the same way.
Smaller commercial customers may primarily pay based on the amount of electricity consumed, measured in kilowatt-hours (kWh).
Larger commercial and industrial customers may also pay charges based on electricity demand, which is measured in kilowatts (kW) or kilovolt-amperes (kVA).
For example, some general service customers have distribution charges calculated using their maximum demand during the billing period.
This means a short period of unusually high demand can affect certain charges, even if the business's overall electricity consumption hasn't changed significantly.
Ontario also has a program called the Industrial Conservation Initiative (ICI).
Under this program, eligible Class A electricity customers pay a portion of their Global Adjustment costs based on their contribution to the province's five highest electricity demand hours during a 12-month base period.
By reducing consumption during those specific hours, participating businesses may reduce their Global Adjustment costs in the following adjustment period.
The Independent Electricity System Operator (IESO) explains how the province calculates peak demand factors and Global Adjustment charges.
It's important to note that the ICI isn't available to every business. Reducing your building's monthly demand peak is also different from reducing consumption during Ontario's province-wide peak hours.
Before investing in battery storage, businesses should understand which charges apply to their facility.
Battery storage allows businesses to save electricity and use it at a later time.
A commercial battery system can be programmed to release stored energy when electricity demand increases, reducing the amount of power the building needs to draw from the grid.
Consider a distribution centre in Toronto.
Throughout the day, the building uses electricity for lighting, ventilation, and warehouse equipment. During certain operating hours, several systems may run at full capacity.
A battery could supply part of that additional demand, potentially reducing peak-related charges.
Battery storage can also be used to shift electricity consumption between different periods.
For example, depending on the system design and electricity rate, a business might charge a battery during a period of lower electricity costs and discharge it later.
Ontario's Independent Electricity System Operator explains how energy storage works, including its ability to draw electricity during off-peak periods and make it available when demand is higher.
However, battery systems have operating costs and efficiency losses. Moving electricity from one period to another doesn't automatically guarantee savings.
Peak shaving is worth examining for businesses that experience high or fluctuating electricity demand.
Manufacturing facilities often use machinery that requires substantial amounts of power.
When multiple machines run simultaneously, electricity demand can increase significantly.
Battery storage may help manage these peaks without requiring businesses to interrupt production.
Large warehouses may use electricity for cooling, ventilation, lighting, loading equipment, and automated systems.
Businesses with predictable high-demand periods may be able to use stored electricity to reduce their grid demand.
Commercial buildings can experience higher electricity demand during Ontario's hot summer months, especially when air-conditioning and ventilation systems operate alongside other equipment.
For buildings with demand-related charges, battery storage may help manage these periods.
However, not every commercial property will benefit equally. A business with consistent electricity consumption and relatively low demand charges may have fewer opportunities to save through peak shaving.
No. Battery storage can operate independently of solar panels.
Depending on the system design, batteries can store electricity purchased from the grid and use it later.
However, combining solar panels with battery storage may provide businesses with more flexibility.
Solar panels generate electricity during daylight hours, reducing how much power a building needs to purchase from the grid.
If the system includes compatible battery storage, some of that solar energy can be saved for later use.
For example, a Toronto warehouse might use solar electricity during regular operating hours and stored energy during an evening shift.
This doesn't mean every business needs both technologies.
A facility with high daytime electricity consumption may benefit from solar panels alone, while another business with significant peak-demand charges may find battery storage worth evaluating.
For businesses exploring onsite electricity generation, EcoNova Solar offers solar installation and energy solutions for properties across Ontario.
Power interruptions can create serious problems for businesses that depend on continuous electricity.
A refrigerated warehouse could risk losing temperature-sensitive products. A manufacturing facility may need to stop production, while an office building could experience disruptions to essential systems.
Certain battery storage systems can provide backup electricity during an outage, but peak shaving and backup power are not the same thing.
A battery designed for peak shaving is primarily used to manage electricity demand.
A backup power system requires appropriate electrical equipment and controls to safely supply power when the grid is unavailable.
Some systems can handle both applications, but they must be designed for those requirements.
The amount of backup power available also depends on battery size, equipment requirements, and the duration of the outage.
Before investing in commercial battery storage, it's worth understanding how your building uses electricity.
Start by reviewing your electricity bills over the past 12 months.
Your electricity rate classification matters, too.
For example, an eligible Class A customer participating in Ontario's Industrial Conservation Initiative may have a different financial opportunity from a smaller commercial business billed primarily for energy consumption.
Businesses should also consider installation costs, battery life, efficiency losses, maintenance, and potential electrical upgrades.
The goal isn't simply to install battery storage. It's to determine whether the investment could provide meaningful savings for your facility.
Peak shaving can help certain businesses manage electricity demand, but it isn't the right solution for every commercial property.
For some facilities, battery storage may help reduce demand-related costs. Others may benefit more from improving equipment efficiency, adjusting operating schedules, or generating their own electricity with solar panels.
The best starting point is understanding where your electricity costs come from and which changes could make a difference.
At EcoNova Solar, we help property owners explore solar and energy solutions across Toronto and Ontario.
Wondering which energy solution makes sense for your business? Visit EcoNova Solar to discuss your property, energy consumption, and long-term electricity goals.
Tell us about your property and electricity usage. We will prepare a free assessment with the recommended system, projected savings, available incentives and estimated payback.